Solar Panel
A solar panel (also known as solar module or photovoltaic module/panel) is an assembly of solar cells. Solar objects are typically parented to inverter or inverter_dyn, but can also run headless with internal default voltage/current placeholders (with warnings).
A minimal model could be created via:
object solar {
panel_type SINGLE_CRYSTAL_SILICON;
SOLAR_POWER_MODEL DEFAULT;
efficiency 0.2;
parent inverter1;
area 2500;
}
Properties
| Property name | Type | Unit | Description | Default |
|---|---|---|---|---|
| pvc_Pmax_calc_simp_mode | bool | n/a | If true, PV-curve max power is approximated as pvc_U_m_V * pvc_I_m_A. |
TRUE |
| t_ref_cels | double | degC | Reference cell temperature for PV-curve equations. | 25 |
| S_ref_wpm2 | double | W/m^2 | Reference insolation for PV-curve equations. | 1000 |
| pvc_a1_inv_cels | double | 1/degC | PV-curve temperature coefficient for current term dI. |
0 |
| pvc_b1_inv_cels | double | 1/degC | PV-curve temperature coefficient for voltage term dU. |
0 |
| pvc_U_oc_V | double | V | PV open-circuit voltage parameter. | 0 (auto-derived in PV_CURVE mode if needed) |
| pvc_I_sc_A | double | A | PV short-circuit current parameter. | 0 (auto-derived in PV_CURVE mode if needed) |
| pvc_U_m_V | double | V | PV voltage at maximum power point. | 0 (auto-derived in PV_CURVE mode if needed) |
| pvc_I_m_A | double | A | PV current at maximum power point. | 0 (auto-derived in PV_CURVE mode if needed) |
| MAX_NR_ITERATIONS | int16 | n/a | Maximum Newton-Raphson iterations for PV_CURVE solver. | 32767 |
| x0_root_rt | double | n/a | Initial guess offset ratio for Newton-Raphson root search. | 0.15 |
| DOA_NR_ITERATIONS | double | n/a | Newton-Raphson degree-of-accuracy threshold. | 1e-5 |
| panel_type | enumeration | n/a | Panel technology. Values: SINGLE_CRYSTAL_SILICON, MULTI_CRYSTAL_SILICON, AMORPHOUS_SILICON, THIN_FILM_GA_AS, CONCENTRATOR. | SINGLE_CRYSTAL_SILICON |
| SOLAR_TILT_MODEL | enumeration | n/a | Tilt/irradiance model. Values: DEFAULT, SOLPOS, PLAYERVALUE. | DEFAULT |
| SOLAR_POWER_MODEL | enumeration | n/a | Power model. Values: DEFAULT, FLATPLATE, PV_CURVE. | DEFAULT |
| a_coeff | double | n/a | Module temperature correction coefficient a. |
-2.81 |
| b_coeff[s/m] | double | s/m | Module temperature correction coefficient b. |
-0.0455 |
| dT_coeff[mmdegC/kW] | double | mmdegC/kW | Module temperature correction coefficient dT. |
0.0 |
| T_coeff[%/degC] | double | %/degC | Maximum-power temperature coefficient. | -0.5 |
| NOCT[degF] | double | degF | Nominal operating cell temperature. | 118.4 |
| Tmodule[degF] | double | degF | Module temperature used in legacy power calculations. | Computed |
| Tambient[degC] | double | degC | Ambient temperature used in model calculations. | 25.0 |
| wind_speed[mph] | double | mph | Ambient wind speed (used in FLATPLATE mode). | 0.0 |
| ambient_temperature[degF] | double | degF | Ambient air temperature input. | 77 |
| Insolation | double | W/sf | Effective incident irradiance. | 0 |
| Rinternal | double | Ohm | Internal resistance (legacy placeholder). | 0.05 |
| Rated_Insolation | double | W/sf | Rated insolation value used in scaling. | 92.902 |
| Pmax_temp_coeff | double | n/a | Temperature coefficient for power output. | Panel-dependent (set during init) |
| Voc_temp_coeff | double | n/a | Temperature coefficient for open-circuit voltage. | Panel-dependent (set during init) |
| V_Max | double | V | Maximum operating voltage of the PV module. | 27.1 |
| Voc_Max | double | V | Maximum open-circuit voltage of the module. | 34.0 |
| Voc | double | V | Current open-circuit voltage value. | 34.0 |
| efficiency | double | unit | Conversion efficiency from insolation to DC power. | Panel-dependent (defaults from panel type) |
| area | double | sf | PV array area. | 0 |
| soiling | double | pu | Array soiling factor. | 0.95 |
| derating | double | pu | Panel derating factor. | 0.95 |
| Tcell | double | degC | PV cell temperature. | 21.0 |
| rated_power | double | W | Rated array power (Max_P). |
0 (auto-derived if omitted) |
| P_Out | double | kW | DC power output to inverter. | Computed |
| V_Out | double | V | DC output voltage to inverter. | Computed |
| I_Out | double | A | DC output current to inverter. | Computed |
| weather | object | n/a | Optional climate object reference. | auto-discovered if available |
| shading_factor | double | pu | Irradiance scaling factor for shading. | 1.0 |
| tilt_angle | double | deg | PV array tilt angle. | 45 |
| orientation_azimuth | double | deg | Cardinal azimuth (0=N, 90=E, 180=S, 270=W). | 180 |
| latitude_angle_fix | bool | n/a | If true, tilt is set from climate latitude. | FALSE |
| default_voltage_variable | double | n/a | Hidden placeholder voltage for headless operation. | hidden |
| default_current_variable | double | n/a | Hidden placeholder current for headless operation. | hidden |
| default_power_variable | double | n/a | Hidden placeholder power for headless operation. | hidden |
| orientation | enumeration | n/a | Orientation type. Values: DEFAULT, FIXED_AXIS (others reserved/not implemented). | DEFAULT |
Example
object solar {
parent inverter1;
panel_type SINGLE_CRYSTAL_SILICON;
SOLAR_POWER_MODEL FLATPLATE;
SOLAR_TILT_MODEL SOLPOS;
orientation FIXED_AXIS;
tilt_angle 30;
orientation_azimuth 180;
shading_factor 0.95;
efficiency 0.2;
area 2500;
}
Orientation
Type of panel orientation. The documented and implemented operating modes are DEFAULT and FIXED_AXIS.
- DEFAULT: ideal-tracking style insolation path.
- FIXED_AXIS: uses fixed
tilt_angleandorientation_azimuthwith the selectedSOLAR_TILT_MODEL.
ONE_AXIS, TWO_AXIS, and AZIMUTH_AXIS are enum placeholders but are not implemented for runtime calculations.
object solar {
orientation FIXED_AXIS;
}
This orientation uses ideal insolation. Insolation is calculated by
Insolation = solar_flux * shading_factor
where the value for solar_flux comes from mapped climate calculations when weather/climate data is available. Without climate data, the model falls back to static behavior and warns.
-
FIXED_AXIS - When orientation is set as FIXED_AXIS, weather, tilt_angle, orientation_azimuth, SOLAR_TILT_MODEL, and shading_factor are all used to calculate the solar radiation.
-
ONE_AXIS - Placeholder only; not implemented
- TWO_AXIS - Placeholder only; not implemented
- AZIMUTH_AXIS - Placeholder only; not implemented
Solar Tilt Model
Underlying solar position and tilt model used to calculate irradiance on the panel. Implemented model types include DEFAULT and SOLPOS for fixed-axis calculations, with PLAYERVALUE for player-driven insolation workflows.
object solar {
SOLAR_TILT_MODEL SOLPOS;
}
-
DEFAULT - The incident solar radiation on a tilted array is calculated using algorithms from Solar Energy Thermal Processes by Duffie and Beckman (1974).
-
SOLPOS - The incident solar radiation on a tilted array is calculated using algoirthms from the [NREL SOLPOS] page and from "Modeling Daylight Availability and Irradiance Components from Direct and Global Irradiance" in Solar Energy volume 44, number 3 by Perez et al.
-
PLAYERVALUE - Bypasses internal tilt-position calculations and expects externally provided/played values (for example
Insolation,ambient_temperature,wind_speed).
Model with DC Bus Model
The solar panel, when properly interfaced with an inverter_dyn object in grid-forming mode, will provide DC bus changes and some minor transient detail. A behavioral model of PV cell is adopted here, the advantage of this model is that it only needs parameters of output characteristics of PV cell such as open-circuit voltage (\(U_{oc}\)), short-circuit current (\(I_{sc}\)), voltage and current at maximum power operating point (\(U_m\) and \(I_m\)).
The formulas which describe the behavioral model are given as below:
| \(\displaystyle{}I=I_{sc}\left[1-C_1\left(\exp{\frac{U-dU}{C_2U_{oc}}}-1\right)\right]+dI\) | (1) |
|---|---|
| \(\displaystyle{}C_1=\left(1+\frac{I_m}{I_{sc}}-\right)\exp{\frac{-U_m}{C_2U_{oc}}}\) | (2) |
| \(\displaystyle{}C_2=\left(\frac{U_m}{U_{oc}}-1\right)\left[\ln{1-\frac{I_m}{I_{sc}}}\right]^{-1}\) | (3) |
| \(\displaystyle{}dU=-b_1U_{oc}(t-t_{ref})\) | (4) |
| \(\displaystyle{}dI=I_{sc}\left[a_1\frac{S}{S_{ref}}\left(t-t_{ref}\right)+\left(\frac{S}{S_{ref}}-1\right)\right]\) | (5) |
Where \(S_{ref}\) and \(t_{ref}\) are light intensity and temperature in standard environment (\(S_{ref}=1000\frac{w}{m^2}\), \(t_{ref}=25^{\circ}C\)), \(S\) and \(t\) are real light intensity and temperature, \(a_1\) and \(b_1\) are parameters that used to revise the output characteristics of PV panel in different environment. \(a_1\) and \(b_1\) are set zero in this instance.
A real PV panel has been modeled according to the formulas above, the output parameters of which are given in Table Table 3:
| PV Panel Variable | Units | Value |
|---|---|---|
| \(\displaystyle{}U_{oc}\) | V | 1005 |
| \(\displaystyle{}I_{sc}\) | A | 100 |
| \(\displaystyle{}U_{m}\) | V | 750 |
| \(\displaystyle{}I_{m}\) | A | 84 |
In GridLAB-D™ simulation, the PV panel is modeled as a controllable current source, with the light intensity (\(S\)), temperature (\(t\)) and voltage of PV panel as inputs. The output of the model is the current of PV panel.
The P-V curve of this PV panel is given in Figure 1, the maximum power is about 1400kW and the voltage at maximum power point is 850V. (\(t=25^{\circ}C, S=600\frac{w}{m^2}\)).