Refrigerator
Warning
This page contains features that are unfinished, were never implemented, or have since been deprecated. We preserve these pages for archival purposes, and also as a foundational resource for prospective developers who may wish to implement the same or similar feature. Many of these pages provide robust explanations of the theory behind a particular module or feature that we hope readers will find useful.
This page does not reflect the current state of GridLAB-D™
Synopsis
object refrigerator {
// residential_enduse properties
shape "type: unknown";
load "power_factor: 0.950000; power.r: 0.000000";
energy +0+0i kVAh;
power +0+0j kVA;
peak_demand +0+0i kVA;
heatgain +0 Btu/h;
cumulative_heatgain +0 Btu;
heatgain_fraction +0 pu;
current_fraction +0 pu;
impedance_fraction +0 pu;
power_fraction +0 pu;
power_factor +0.95;
constant_power +0+0i kVA;
constant_current +0+0i kVA;
constant_admittance +0+0i kVA;
voltage_factor +0 pu;
breaker_amps +0 A;
configuration IS110;
override NORMAL;
power_state OFF;
// refrigerator properties
size +23.9374 cf;
rated_capacity +816.743 Btu/h;
temperature +38.1227 degF;
setpoint +38.3484 degF;
deadband +2.4032 degF;
cycle_time +0 s;
output +0;
event_temp +0;
UA +0.6 Btu/degF*h;
compressor_off_normal_energy +40500;
compressor_off_normal_power +15 W;
compressor_on_normal_energy +252000;
compressor_on_normal_power +120 W;
defrost_energy +1.32e+06;
defrost_power +550 W;
icemaking_energy +18000;
icemaking_power +300 W;
ice_making_probability +0.02;
FF_Door_Openings 0;
door_opening_energy 0;
door_opening_power 0;
DO_Thershold +1.18576e-322;
dr_mode_double +0;
energy_needed +0;
energy_used +0;
refrigerator_power +0;
icemaker_running FALSE;
check_DO 0;
is_240 FALSE;
defrostDelayed +0;
long_compressor_cycle_due FALSE;
long_compressor_cycle_time +0;
long_compressor_cycle_power +120;
long_compressor_cycle_energy +720000;
long_compressor_cycle_threshold +0.05;
defrost_criterion TIMED;
run_defrost FALSE;
door_opening_criterion +0;
compressor_defrost_time +0;
delay_defrost_time +28800;
daily_door_opening 0;
state 0;
}
Related Concepts:
- Residential module
- User's Guide
- Appliances
- house class – Single-family home model.
- residential_enduse class – Abstract residential end use class.
- occupantload – Residential occupants (sensible and latent heat).
- ZIPload – Generic constant impedance/current/power end use load.